EMIX1 | EMIX2增量式測量系統(tǒng)緊湊型測量系統(tǒng),用于線性和徑向測量
分辨率0.01毫米(4邊沿觸發(fā)時(shí))重復(fù)精度±0.001毫米
速度比方波信號(hào)輸出
EMIX1
配有外置讀值電子元件的小傳感器讀頭EMIX2
配有內(nèi)置讀值電子元件和標(biāo)志脈沖的小傳感器讀頭傳感器可以垂直或水平安裝
MECHANICAL DATA
| Measuring principle | incremental |
| Repeat accuracy | ±?1 increment |
| System accuracy in μm at 20 °C | ± (20 + 20 x L), L= measuring length in meters |
| Distance sensor / tape | max. 0.8 mm |
| Sensor housing material | zinc die cast |
| Housing dimensions (L x W x H) | EMIX1: 30 x 10 x 15, EMIX2: 30 x 12.5 x 25 |
| Required magnetic tape | MB20-20-10-1-R |
| Pole pitch | 2 mm |
| ?Max. measuring length | theoretically unlimited |
| Connections | EMIX1: 9 pin D-SUB (male), EMIX2: open cable ends |
| Sensor cable | 1.5 m standard length, others on request, drag chain suitable? |
| Sensor cable bending radius | 60 mm |
| Weight | EMIX1: sensor + D-SUB: approx. 40 g, EMIX2: approx. 35 g (each without cable), cable: approx. 60 g/m |
ELECTRICAL DATA
| Power supply voltage | 10 ... 30 VDC or 5 VDC |
| Residual ripple | 10 ... 30 VDC: <10 %, 5 VDC: ±?25 mV |
| Current consumption | 10 ... 30 VDC: max.?150 mA, 5 VDC: max. 200 mA |
| Output signals | A, A', B, B', Z, Z' |
| Output levels | HTL or TTL |
| Output current per channel | max. 20 mA |
| Resolution (at 4 edge evaluation) | 0.01 mm |
| Index pulse | every 2 mm (periodically), optionally as reference pulse |
| Max. output frequency per channel | 200 KHz |
| Operating speed | 4 m/s |
ENVIRONMENTAL CONDITIONS
| Storage temperature | -25 ... +85 °C |
| Operating temperature | -10 ... +70 °C, -25 ... +85 °C on request |
| Humidity | 95 %, non-condensing |
| Protection class | IP67 |